Lead Arsenate Chemical Storage Specifications

Compliant storage and rental solutions for Lead Arsenate (PbHAsO4). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.

Non-flammableNon-Flammable Storage

Chemical formula

About Lead Arsenate

Lead arsenate is an inorganic lead salt composed from lead(2+) and arsenate dianion. It was widely used in the United States in the 1950's as an insecticide to control pests in fruit orchards, specifically apples and cherries. It has a role as an insecticide, a plant growth regulator and a rodenticide.

Structured hazard data

Hazard class
Acute Tox. 3 H301 Toxic if swallowed. Acute Tox. 3 H331 Toxic if inhaled.
Storage category
Non-Flammable Storage
Flammable
No
Flash point
See SDS
Storage temperature
ambient
Recommended extinguishing agent
Dry Chemical
Compatibility / segregation
Lead Arsenate is not compatible with OXIDIZING AGENTS. (such as PERCHLORATES, PEROXIDES,. PERMANGANATES, CHLORATES, NITRATES,. CHLORINE, BROMINE

Carc. 1A H350 May cause cancer. Repr. 1A H360Df May damage the unborn child. Suspected of damaging fertility. STOT RE 2 H373 May cause damage to organs through prolonged or repeated exposure.

Fire Suppression System

Dry Chemical fire suppression is recommended for Lead Arsenate

  • Water

    Water

  • Dry Chemical

    Dry Chemical · Recommended

  • CO₂ / Other

    CO₂ / Other

Guidance: Dry Chemical fire suppression is generally recommended for Lead Arsenate (PbHAsO4). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Additional extinguishing notes: CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam

Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.

Storage & segregation guidance

Compliant storage and rental solutions for Lead Arsenate should account for its listed hazards (Acute Tox. 3 H301 Toxic if swallowed. Acute Tox. 3 H331 Toxic if inhaled.), climate control needs (ambient), and segregation requirements. Lead Arsenate is not compatible with OXIDIZING AGENTS. (such as PERCHLORATES, PEROXIDES,. PERMANGANATES, CHLORATES, NITRATES,. CHLORINE, BROMINE

Review Segregated storage for incompatible chemicals and Organic peroxide storage building when designing fire rating, containment, and building selection.

Properties: Form: Solid Colour: Off white · Odour: Odourless · Odour threshold: Not determined.

Matched to this chemical

Recommended storage solutions for Lead Arsenate

Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.

  • Non-fire-rated0 HourChemical Storage Shipping

    BoxSAFE CX

    • Non Fire-Rated
    • 8 ft x 40 ft x 8' 5"
    • 50 Qty 55 Gallon Drums
    • 9 Pallets or Totes
    • 302 Square Feet storage
    View product
  • Non-fire-rated0 HourChremical Storage

    Non Fire-Rated

    • 0-Hour Fire-Rated
    • 8 ft x 40 ft
    • 57 Barrels
    • 55 Gal Storage Drums
    View product
  • Non-fire-rated0 HourChremical Storage

    Non Fire-Rate

    • 0-Hour Fire-Rated
    • 8 ft x 20 ft
    • 27 Barrels
    • 55 Gal Storage Drums
    View product

Material handling

How do you manage your bulk chemical storage?

US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

We have solutions designed for your workflow process needs.

Frequently asked questions

How should Lead Arsenate be stored?

Store Lead Arsenate in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Acute Tox. 3 H301 Toxic if swallowed. Acute Tox. 3 H331 Toxic if inhaled.). Climate range guidance: ambient. Compatibility notes: Lead Arsenate is not compatible with OXIDIZING AGENTS. (such as PERCHLORATES, PEROXIDES,. PERMANGANATES, CHLORATES, NITRATES,. CHLORINE, BROMINE US Hazmat Rentals provides compliant chemical storage buildings available for rental.

Is Lead Arsenate flammable?

Lead Arsenate is not flagged as flammable in this database (No). Still verify the SDS and store in compliant containment for its listed hazard class.

What hazard class is Lead Arsenate?

Lead Arsenate is listed as: Acute Tox. 3 H301 Toxic if swallowed. Acute Tox. 3 H331 Toxic if inhaled.. Carc. 1A H350 May cause cancer. Repr. 1A H360Df May damage the unborn child. Suspected of damaging fertility. STOT RE 2 H373 May cause damage to organs through prolonged or repeated exposure.

What fire suppression is recommended for Lead Arsenate?

Dry Chemical fire suppression is generally recommended for Lead Arsenate (PbHAsO4). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.

Is compliant Lead Arsenate storage available for rent?

Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Lead Arsenate. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.